| PARAMETER |
SPECIFICATION |
| Trolley type full digital color Doppler ultrasonic mainframe |
| Ultrasonic host operating system |
Windows operating system |
| Applications |
Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
| Probes |
Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
| Applications and report |
Support abdomen, obstetrics, gynecology, heart, urology, small organs, superficial, blood vessels,pediatrics, etc. advanced measurement software package, report software package, patient management software package |
| carotid artery intima measurement thickness(IMT) |
| Automatic spectral envelope measurement |
| Full digital transmission and reception of beam synthesizer |
| Lifting and rotating platform with adjustable height and movable rotation function |
| Color Doppler imaging(C) |
| Pulse Doppler Imaging(PW) |
| Coherent Contrast imaging(CCI) |
| Continuous wave Doppler imaging(CW) |
| B/C/D Real-time three synchronous imaging |
| Power Doppler imaging(PDI) |
| Direct power Doppler imaging(DPDI) |
| M mode imaging |
| Anatomic M mode imaging |
| Color Doppler M mode imaging |
| Elastography |
| Tissue Doppler imaging(TDI) |
| Strain rate imaging (SRI) |
| Tissue harmonic imaging(THI) |
| Fusion harmonic imaging(FHI) |
| Speckle Reduce imaging(SRI) |
| Panoramic imaging |
| Deflection imaging |
| Trapezoidal imaging |
| Adaptive velocity optimization |
| Free hand 3D |
| Real time 3D imaging(3D/4D) |
| DICOM3.0 |
| Monitor |
≥21.5 inch,high definition ultrasonic display |
| ≥10.4 inch touch screen |
| Physical clipboard |
save the image on the left side of the screen, which can be directly saved or
deleted. |
| The system has the function of on-the-spot upgrade |
| Presupposition |
for different inspection of the viscera, preset the inspection conditions for the
best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. |
| Probe interface |
4 |
| Chinese and English System, Chinese and English input, optional |
| Depth |
≥360mm |
| Extended imaging |
| Probes |
| Convex probe |
Fundamental Frequency:
2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,
Harmonic Frequency:
4.0MHz/4.6MHz/5.0MHz |
| Linear probe |
Fundamental Frequency:
4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz,
Harmonic Frequency:
8.0MHz/9.2MHz/10.0MHz |
| Trans-vaginal probe |
Fundamental Frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz
Harmonic Frequency:
6.0MHz/7.0MHz/8.0MHz |
| Micro-convex probe |
Fundamental Frequency:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz,
Harmonic Frequency:
6.0MHz/7.0MHz/8.0MHz |
| Cardiac probe |
Fundamental Frequency:
1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz,
Harmonic Frequency:
3.4MHz/3.8MHz/4.2MHz |
| 4D Volume probe |
Fundamental Frequency:
2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz,
Harmonic Frequency:
4.0MHz/5.0MHz/6.0MHz |
| 2D imaging mode |
| Gain |
0-100,Step 2 adjustable |
| TGC |
8 segment adjustable |
| Maximum focus point |
≥7, which can be moved throughout the whole process |
| Speckle reduction |
0-5,5 level |
| Space Synthesis |
0-2,2 level(Liner probe: 3 level, cardiac probe:0) |
| Dynamic |
30-180,35 level,step 5 adjustable |
| Line density |
low、middle、high,3 level |
| Frame correlation |
0-4,4 level |
| Noise reduction |
0-5,5 level |
| Edge Enhancement |
0-5,5 level |
| Sound power |
2-10, 9 level |
| Grey scale |
0-67, 67 level |
| False color |
0-67,67 level |
| Image style |
Soft-Comparison,2 level |
| The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color,
gray scale and other 11 parameters can be adjusted |
| Color Doppler imaging mode |
| Blood gain |
0-100,Step 2 |
| Parameter display |
Velocity、Variance |
| B-Restrain(B/W restrain) |
0-7, 7 level |
| Speed Through |
0-8, 8 level |
| Sampling number |
6-24, 7 level |
| Blood flow preferred |
0-8, 8 level |
| Filtering |
1-6, 6 level |
| Sound power |
2-6, 4 level |
| Noise reduction |
0-4, 4 level |
| Smooth treatment |
0-4, 4 level |
| Frame correlation |
0-6, 6 level |
| Chromatography(Blood flow graph) |
0-37, 37 level |
| Line density |
Low-Middle-High, 3 level |
| Frequency |
4 level adjustable |
| Velocity:Minimum 0.4K,Maximum 40.5K
Convex probe:0.4K-4.3K-38.5K
Linear probe:0.4K-14.7K-39.0K
Trans-vaginal probe:0.4K-7.8K-39.7K
Volume probe:0.4K-4.2K-34.8K
Micro-convex probe:0.4K-10.3K-40.5K
cardiac probe:0.4K-7.8K-39.7K |
| PS: The frequency of the probe changes and the frequency value changes |
| PS: Frame rate changes with speed |
| Pulse wave Doppler (PW ) |
| Gain |
0-100,Step 2 |
| Spectrum envelope function |
real time automatic spectrum envelope, manual spectrum envelope, and
other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close |
| Sample volume |
0.5mm~30mm |
| Blood angel |
-75—75 degree,Step 5 |
| False color |
0-67, 67 level |
| Dynamic range |
20-40, 4 level |
| Filter |
0-9, 9 level |
| Smooth treatment |
1-4, 4 level |
| Sound power |
2-5, 4 level |
| Volume |
0-100, 10 level,Step 10 |
| Audio filtering |
0-4, 4 level |
| Base line |
-1.0~1.0 |
| Grey map |
0-67, 67 level |
| Scan velocity |
100-500, 6 level |
| PRF:Minimum 0.5K,Maximum 87.5K
Convex probe:0.5K-4.3K-63.3K
Linear probe:0.5K-14.5K-78.4K
Trans-vaginal probe:0.5K-8.1K-78.4K
Volume probe:0.5K-4.2K-53.8K
Micro-convex probe:0.5K-10.3K-81.1K
cardiac probe:0.5K-4.3K-87.5K |
| Frequency |
4 level |
| PS: The frequency of the probe changes and the PRF value changes |
| PS: The frequency of the probe changes and the frequency value changes |
| Continuous Wave Doppler (CW) |
| Support probe |
Cardiac probe |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,Step 2 |
| Sampling line position is adjustable |
| PRF |
0.9K~36.1K |
| Baseline |
-1.0~1.0 |
| Blood angel |
-75~75 degree |
| Grey map |
0-67 |
| Scan velocity |
100-300 |
| False color |
0-67 |
| Dynamic range |
20-40 |
| Filtering |
0-9,9 level |
| Smooth treatment |
1-4 |
| Frequency |
2.0MHz/2.3MHz/2.5MHz/3.0MHz,4 level adjustable |
| Sound power |
2-5 |
| Volume |
0-100 |
| Audio Filtering |
0-4 |
| Anatomical M imaging |
| Support probe |
Convex probe, Linear probe, Cardiac probe |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,Step 2 |
| M Sampling line angel is adjustable |
| M Sampling line length is adjustable |
| Sampling line |
3,Can be displayed or hidden separately |
| Blood flow M model (MC ) |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,Step2 |
| MC Sampling line angel is adjustable |
| MC Sampling line length is adjustable |
| Frequency |
4 level |
| Sampling number |
6-24 |
| Speed through |
0-8, 8 level |
| Scan velocity |
150-500 |
| Frame correlation |
0-6, 6 level |
| Filtering |
1-6,6 level |
| Blood flow preferred |
0-8,8 level |
| Smooth treatment |
0-4,4 level |
| Map |
0-37, 37 level |
| Elastography |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,Step 2 |
| B/E, Double real-time display on the same screen |
| Probe displacement curve display |
Up/Down |
| Pressure indicator bar display |
| Frequency |
8-9 level,Adjustable;According to the probe display |
| Noise reduction |
0-2, 2 level |
| Frame correlation |
0-3, 3 level |
| Comparison |
0-13, 13 level |
| False color |
0-3, 3 level |
| Don’t support cardiac probe |
| Tissue Doppler imaging (TDI ) |
| Support probe |
Cardiac probe |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,step 2 |
| ROI area adjustable |
| Sampling number |
6-24 |
| Velocity |
0.4K-8.0K |
| Frame correlation |
0-6,6 level |
| Tissue preferred |
0-7, 7 level |
| Frequency |
2.0MHz/2.3MHz/2.5MHz/3.0MHz |
| Support color reversal |
| Strain rate imaging |
| Support probe |
Cardiac probe |
| Adjustment of B mode parameters is switchable |
| ROI area adjustable |
| Gain |
0-100,Step 2 |
| Sampling number |
6-24,6 level |
| Axial average |
1-4, 4 level |
| Velocity |
0.4K-8K |
| Frame correlation |
0-6, 6 level |
| Tissue optimization |
0-7,7 level |
| Panoramic imaging |
| Support probe |
Linear probe |
| Speckle Reduction |
0-5, 5 level |
| Deflection imaging |
| Support probe |
Linear probe |
| Adjustment of B mode parameters is switchable |
| Deflection angel |
8 level |
| Speckle reduction |
0-5, 5 level |
| Dynamic rate |
~250dB,Step 5 |
| Line density |
low-middle-high,3 level |
| Frame Correlation |
0-4, 4 level |
| False color |
0-67, 67 level |
| Image style |
Soft-Comparison,2 level |
| Noise reduction |
0-5, 5 level |
| Edge Enhancement |
0-5,5 level |
| Sound power |
2-10,8 level |
| Grey map |
0-67,67 level |
| Trapezoidal imaging |
| Probe support |
linear probe |
| Adjustment of B mode parameters is switchable |
| Deflection angel |
8 level |
| Speckle reduction |
0-5, 5 level |
| Dynamic rate |
30-180,Step 5 |
| Line density |
low-middle-high,3 level |
| Frame Correlation |
0-4,4 level |
| False color |
0-67, 67 level |
| Image style |
Soft-Comparison,2 level |
| Noise reduction |
0-5, 5 level |
| Edge Enhancement |
0-5,5 level |
| Sound power |
2-10,8 level |
| Grey map |
0-67, 67 level |
| Space Synthesis |
0-2, 2 level |
| Freehand 3D imaging |
| Support probe |
convex probe, linear probe |
| Display model |
4 pictures |
| Image Rotation X/Y/Z Axis |
| Multi-slice Visibility |
| Real-time 4D imaging |
| Support probe |
4D volume probe |
| Adjustment of B mode parameters is switchable |
| Gain |
0-100,Step 2 |
| Display model |
one image、two images、four images |
| Image Rotation |
X/Y/Z Axis |
| Multi-slice Visibility |
| Light&Shade inversion |
| Smooth |
0-4, 4 level |
| Threshold level |
0-129, Step 3 |
| Transparency |
1-509,Step 10 |
| Render type |
4 kinds,Surface、maximum、minimum、perspective |
| Extended Imaging |
| Gain |
0-100,Step 2 |
| TGC |
8 segment adjustable |
| Maximum focus point |
≥7, which can be moved throughout the whole process |
| Speckle reduction |
0-5,5 level |
| Space Compound |
0-2,2 level(Linear probe: 3 level,don’t support cardiac probe) |
| Dynamic range |
30-180,35 level,Step 5 |
| Line density |
Low、Middle、High,3 level |
| Frame correlation |
0-4,4 level |
| Noise reduction |
0-5,5 level |
| Edge enhancement |
0-5,5 level |
| Sound power |
2-10, 9 level |
| Grey map |
0-67, 67 level |
| False color |
0-67,67 level |
| Image style |
Soft-Comparison,2 level |
| Extended level: Maximum 72 level
Convex probe:9 level
Trans-vaginal probe:72 level
Micro-convex probe:29 level
Cardiac probe:40 level
4D Volume probe:17 level |
| PS:The screen has real-time display of voice power, probe frequency, dynamic range, pseudo
color, gray scale and other 11 parameters can be adjusted |
| PS: When the probe scan range reaches the maximum, the space synthesized is 0. |
| Measurement and analysis function |
| General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume
(ellipse), area ratio, diameter, joint angle |
| Cardiac |
Automatic spectrum envelope、LV、Main Pulmonary artery diameter、RVEDd、RVEDs、LVM、LAV、HR、MVF、AO、AR、LVOT、TVF、Pulmonic valve、Pulmonary vein、RV、Doppler fetal heart sound、LVET、LVM、LVMI、AV |
| Vascular |
carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall) |
| OB |
Fetal routine、AFI、TW、GS、CRl、OFD、HL、ulna、NT、Fibula、Nbonel、Radial、Tibia |
| GYN |
uterus、cervix、corpus uteri/cervix uterus、left ovarian vein、right ovarian vein、dominant follicle、intima thickness |
| Urology |
prostate、residual urine、left kidney、right kidney、left suprarenal vein、right suprarenal、left testis、right testis、left seminal vesicle、right seminal vesicle |
| Abdomen |
liver、CHD、partal vein diameter、cholecyst、CBD、pancreas、spleen、Internal diameter of abdominal aorta、kidney |
| Small parts |
Thyroid |
| Software package |
Measurement package、Software package、Medical records management
software package |
| Graphic and text management system |
| Host build in 2 hard disk(SSD 120+1T),Start fast and stable |
| Movie playback |
≥1200 frames |
| Internal file information management system: can record patient number, name, check number,
check date and so on, and can be searched and managed by numbering, checking number, name
and so on. |
| Type of report |
16 |
| One key fast report graphic and text management |
| Interface |
| USB interface |
4 |
| HDMI interface |
1 |
| RJ-45 interface |
1 |
| Grounding wire interface |
1 |
| DVD RW |
1 |
| Configuration |
| Trolley type full digital color Doppler ultrasound diagnostic system |
| Probe |
convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional) |
| ≥13 quick adjusting knobs |