Categories:

Veterinary Anesthesia machine

Feature

-No electricity will be needed, only manual operation

-Module rack with polyester medical material, high strength and light weight.

-Superior thin spray technology, delicate color, beautiful and durable.

-High precious vaporizer, Halothane, Enflurane, Isoflurane and Sevoflurane could be choosen freely

-Main unit are only 2Kg (w/o vaporizer), light weight and easy to move

-With a dedicated handle, could move by hand-pull.

-Two gas sources: O2, N2O, suitable for more patient type

-Classical CO2 circle absorber with 1 canister, low resistance, minimum gas leakage, 60cmH2O peak pressure solution.

-Ventilator (Optional): TH-1, TH-1A

-3 types of Small Vaporizers and 4 types of Big Vaporizers for choice.

PARAMETER SPECIFICATION
Ventilation mode Closed, Semi-closed, Semi-open
Application 2-100KG animals
Gas source O2, N2O   0.25Mpa~0.65Mpa
Two tube (O2, N2O) Scope,0—10L/min.With linkage device,O2 concentration not low than 25%
O2 flush more than 25L/min
Respiratory mode Manual, Oxygen
TV 50~2000mL
I:E according to the doctor operation
BPM according to the doctor operation
APL Valve pressure 0.5-6KPa
Monitoring Airway pressure, respiratory mode
Three Gauges one for O2, one for N2O, one for airway pressure
Environment Requirement
Temperature Operation: 18~36 ºC
Storage: -20~55 ºC
Humidifier Operation:45%~75%
Storage:≤93%
Atmospheric pressure Operation:0.95~1.05 bar
Storage: 500hPa~1060hPa
Altitude Operation:500 to 800mmHg (3565~-440m)
Storage:375 to 800mmHg (5860~-440m)

Anesthesia Ventilators (Optional)

Two Anesthesia Ventilators (Optional)

– Independent Anesthesia Ventilator, with IPPV and Manual mode

– With necessary monitoring and alarm function, to make sure the operation safety

– Gas supply: O2, or Air

– With international connector, can be matched with various brands of anesthesia machines

 

TH-1A Parameter

– Respiration mode: IPPV, SIMV, Manual

– Respiratory frequency: 1 to 65BPM

– Display: 5.5´ SNT screen

– I:E ratio: 8:1~1:8

– Waveform: P-t, V-t

– Tidal volume: 50ml~1600ml

– Monitor Parameters: Tidal volume; Minute Ventilation; Peak

 

TH-1 Parameter

– Control method: Gas driving electronic controlled

– Breath frequency: 1~90BPM

– Display: High light LED display

– I:E ratio: 4:1~1:6

– Respiration mode: IPPV, Manual

– Tidal volume: 50~1500ml

– Monitor Parameters: Tidal volume; Minute Ventilation; Breath Frequency; Airway Pressure

– Independent Anesthesia Ventilator, with IPPV and Manual mode

– With necessary monitoring and alarm function, to make sure the operation safety

– Gas supply: O2, or Air

– With international connector, can be matched with various brands of anesthesia machines

Be the first to review “Veterinary Anesthesia machine”

Your email address will not be published. Required fields are marked *

There are no reviews yet.

Be the first to review “Veterinary Anesthesia machine”